EAM-T6A

eam-raft

APPROVALS

USA: FAA TSO-C70a, Type I
Japan: JCAB CARJ Article 152
Australia: CAA CAO 103.15
Germany: LBA 40.320

R0425A109:
Canada: CAA ANO II, No.8 Schedule II

- For commercial airlines and Air Cargo use
- Twin tube
- Rated capacity 6, Overload capacity 9
- Compact, lightweight. Constructed of Polyurethane.
- High tech inflation system
- Competitively priced

PART NUMBER: R0425AXXX

SPECIFICATIONS

Capacity

Rated: | Overload: 9 Persons

Approval

USA: FAA TSO-C70a, Type I
Japan: JCAB CARJ Article 152
Australia: CAA CAO 103.15
Germany: LBA 40.320

R0425A109:
Canada: CAA ANO II, No.8 Schedule II


Color Tube: YellowCanopy: Fluorescent OrangeStabilizing Bags: Fluorescent OrangeCarrying Case: Yellow
Diameter Raft Tube 10.5" (267mm)
Inflated Volume: @ 1.50 psig

Tube 1: 9.8 ft³ (0.28 m³)
Tube 2: 9.8 ft³ (0.28 m³)
Total: 19.6 ft³ (0.56 m³)

Tube Volume Per Person: @ rated capacity 3.26 ft³ (0.0925 m³)
Total Tube Buoyancy 1534 lbs. (695.8 kg)
Buoyancy Per Person: @ rated capacity 255.6 lbs. (115.9 kg)
Total Deck Area 21.6 ft² (2.01 m²)
Deck Area Per Person: @ rated capacity 3.6 ft² (0.33 m²)
Tube Operating Pressure

Minimum: 1.5 psig (0.10 bar)
Nominal: 2.0 psig (0.14 bar)
Maximum: 3.0 psig (0.21 bar)

Pressure Relief Valves

Open: 2.5 - 3.0 psig (0.17 - 0.21 bar)
Close: 2.0 psig (0.14 bar)

Tube Burst Pressure Over 6 psig (0.4 bar)
Inflation System

R0425A1XX:
CO₂ System (2 cylinders)
Cylinder Size: 82 in³
Cylinder Type: US DOT-3AA2100, Steel
Charge Pressure: 2100 psi
Charge Weights: CO₂: 1.98 to 2.04 lbs. (0.898 to 0.925 kg)

R0425A3XX, A6XX:
Lightweight System (1 cylinder)
Cylinder Size: 144 in³
Cylinder Type: DOT-SP 9894-4500, TC-3 HWM 310
Charge Pressure: 4500 psi
Charge Weights: CO₂ : 1.00 to 1.02 lbs (0.434 to 0.462 kg)
Charge Weights: N₂ : 1.33 to 1.37 lbs (0.603 to 0.621 kg)

Environmental Limits
Temperature
Humidity

Up to 95% relative humidity

Altitude -2000 to 45,000 ft. above sea level
Service Life

Indefinite if raft continues to pass periodic maintenance inspection

Frequency Of Inspection

R0425A1XX:
12 months from date of manufacture for first maintenance inspection, every 12 months for subsequent inspections

R0425A3XX, A6XX:
36 months from date of manufacture for first maintenance inspection, every 36 months for subsequent inspections